Article: Laparoscopic partial nephrectomy of solid renal masses without hilar clamping using a monopolar radiofrequency device (TissueLink).(Section on Urology)(Brief Article)
- Article from:
- Southern Medical Journal
- Article date:
- October 1, 2004
- Author:
CopyrightCOPYRIGHT 2004 Southern Medical Association. This material is published under license from the publisher through the Gale Group, Farmington Hills, Michigan. All inquiries regarding rights should be directed to the Gale Group. (Hide copyright information)
|
We reviewed our initial experience with laparoscopic partial nephrectomy for solid renal masses without clamping the renal vasculature using a monopolar device with low-volume saline irrigation for blunt dissection, hemostatic sealing, and coagulation of the renal parenchyma (TissueLink). From September 2002 to January 2004, 16 patients underwent transperitoneal LPNx. In all cases, the renal hilum was dissected without vascular clamping. Either the TissueLink DSTM dissecting sealer or the TissueLink Floating Ball was used to bluntly dissect the tumor free, while simultaneously sealing and coagulating the bleeders. Of the 16 patients, 14 had solid renal masses and 2 had ...