Article: Sulfate resistances of different types of Turkish Portland cements by selecting the appropriate test methods.

Abstract

The sulfate resistance of 5 different types of Turkish portland cements were compared using ASTM C 452 and ASTM C 1012 standards. All of the cements, except for sulfate resisting cement, were prepared from the same clinker. As it was expected, ASTM C 452 test was found to be insufficient for determining the sulfate resistance of blended cements. ASTM C 1012 test is more realistic than C 452. It was observed that the addition of some mineral admixtures in small amounts to an ordinary portland cement having a moderate sulfate resistance (

Keywords: Sulfate attack; Mortar bar; Blended cement; Pozzolan

1. Introduction

Concrete deterioration due to ...

Related newspaper, magazine, and journal articles:

 
 
Newsweek Harper's Magazine The Washington Post Chicago Tribune Crain's Chicago Business PRNewswire Pediatric News The Nation Advertising Age The Economist (US) A FREE trial gives you access to over 80 million articles! Access over 6,500 publications with a FREE trial!