Article: Data on experimental toxicology described by L. Golanski et al.(Report)

"In this study, different conventional personal protection devices ( fibrous filters, cartridges for respirators, protective clothing, and gloves) well qualified for micron particles were tested with graphite nanoparticles ranging from 10 to 100 nm ( electrical mobility diameter). For this purpose, two specific test benches were designed: one for filter-based devices which are tested under a controlled air flow and other for gloves and protective clothing based on the ''through diffusion method.'' The penetration versus particle size shows for most tested filter media the behavior predicted by the theoretical Brownian capture: penetration decreases when particle diameter ...